Resilient Flooring 09650
Section 09650
PART 1. GENERAL
1.XX QUALITY ASSURANCE
A. Standards: Meet
requirements of Resilient Floor Covering Institute.
B. Moisture Tests: Owner
will employ services of an Independent Testing Laboratory (ITL) for testing the
moisture content of concrete slabs in accordance with requirements of ASTM F
l869-98, Standard Test Method for Measuring Moisture Vapor Emission Rate of
Concrete Subfloor using Anhydrous Calcium Chloride.
1.XX PROJECT/SITE
CONDITIONS
A. Environmental
Requirements: Maintain room temperature and humidity levels before, during and
after installation as required by flooring manufacturer.
PART 3. EXECUTION
3.XX EXAMINATION
A. Verify that concrete
slab over vapor barrier meets moisture tests.
B. Verify that finish floor
tolerances meet requirements shown in Section 03300 Concrete.
C. Do not proceed with
installation until verifications indicate requirements are met.
D. Notify Architect if
verifications indicated non-compliance with Contract Documents.
|
ASTM |
Carpet
& Rug Institute |
|
|
|
|
Resilient Floor Covering
Institute |
|